Features
Tech Specs
Resources
High-voltage safety compliance testing: Supports insulation resistance (0.1MΩ–500GΩ) and DC/AC withstand voltage testing, ensuring battery systems meet international safety standards.
Intelligent alarming and protection: Combines hardware-level overvoltage/overcurrent/overtemperature protection with software-programmable safety thresholds (voltage/current limits) for dual-layer risk mitigation.
Failure mode simulation: Integrates short-circuit detection, HVIL (High Voltage Interlock) verification, and simulated collision signals to expose design flaws proactively.
Integrated charge/discharge: Single-channel 40kW power with 0-200V/±200A range, covering full lifecycle testing of power batteries.
Accurate resistance diagnostics: Dual-mode DCIR (±0.05% accuracy) and ACIR (3mΩ–300Ω range) measurements to rapidly identify cell inconsistencies.
Dynamic performance validation: Current response time ≤3ms and minimum step duration 0.1s, compatible with fast-charging protocol validation and transient condition simulation.
Full BMS functional verification: Supports CAN communication (DBC configuration), SOC calibration, cell balancing diagnostics, and fast/slow charge state simulation for BMS-battery system co-testing.
Multi-dimensional data cdomparison: Automatically aligns BMS-reported data (voltage/temperature/voltage deviation) with device-measured values, visualizing accuracy deviations in real time.
Customizable workflows: Define test parameters, items, and sequences flexibly.
Data traceability: Supports TCP/IP communication and wireless barcode scanners (1D/2D codes) to automatically link test data with battery IDs.
One-click reporting: Exports test results to Excel/TXT formats with automatic synchronization to MySQL databases.
Multi-protocol support: CAN/CANFD, RS485, RS232, Line, LAN.
MES integration: Compatible with custom MES systems via open APIs for secondary development.
BMS universal compatibility: Built-in DBC converter for multi-standard BMS interfaces.
Multi-device synergy: Controls environmental chambers, chillers, and auxiliary equipment for complex scenario simulations.
Equipment name | EOL Battery Testing System |
---|---|
Model | CE-6002-200V200A-EOL |
Charge/Discharge Testing | |
Voltage Range | 12V~200V |
Voltage Accuracy | ±0.02% F.S. |
Current Range | 0A~200A |
Current Accuracy | ±0.05% F.S. |
AC Impedance Meter | |
Range | 3mΩ–300Ω |
Accuracy | ±0.5% rdg ±10 dgt |
Resolution | 0.1μΩ |
Withstand Voltage Tester | |
DC | 0.05kV~6kV |
AC | 0.05kV~5kV |
Multimeter | |
DCV | 100mV~1000V |
Resolution | 6½ digits |
Insulation Resistance Simulator | |
Resistance Range | 50Ω~1000MΩ |
Resolution | ±50Ω |
I/O Communication | |
I/O | 4× CAN
4× 485 1× RS232 6× Activation Signals |
Voltage&Current Accuracy: ±0.01% F.S.
Recording Frequency: 1000Hz
Current Response Time: ≤20μs
CV Testing
Type-C Power Port
6-Range Current Measurement
Voltage & Current Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Energy Efficiency: >65%
Off-Line Test: 1GB
Voltage & Current Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Energy Efficiency: >65%
Off-Line Test: 1GB
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Minimum Pulse Width: 500ms
Off-Line Test: 1GB
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 100Hz
Number of Channels: 160CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(0℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤30min
(25℃~60℃≤30min)
Cooling Efficiency: 77℉~32℉≤50min
(25℃~0 ℃≤50min)
Voltage & Current Accuracy: ±0.05% F.S.
Sampling Time: 100ms
Number of Channels: 16CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(15℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤50min
(25℃~60℃≤50min)
Cooling Efficiency: 77℉~59℉≤60min
(25℃~15℃≤60min)